SENSOR GROUPS
DOOR/WINDOW
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 29 64
© 11/4/13 All rights reserved
GROUP
NAME
SUPERVISED
SCENARIO
10
Entry/Exit Delay
Y
Allows you to exit during countdown after selecting arming type and
when opened starts countdown before triggering alarm
13
Instant Perimeter
Y
Door or window that triggers alarm instantly when system is armed
14
Instant Interior
Door
Y
Interior door that triggers alarm instantly when system is armed
25
Local Safety Sensor
Y
Regardless of arming state, this device triggers a chime if it is opened
(non-reporting to central station) Great for medicine cabinets, pool
gates, chemical storage, etc.
8
Reporting Safety
Sensor
Y
Regardless of arming state, this device triggers a chime or an alarm if
it is opened. Intended for gun safes, valuables safe, etc.