SENSOR GROUPS
DOOR/WINDOW
GROUP
NAME
SUPERVISED
SCENARIO
10
Entry-Exit- Normal
Delay
Y
Allows you to exit during countdown after selecting arming type
and when opened starts countdown before triggering alarm.
Times determined by “Normal Entry-Exit Delay” in “Timers” app.
12
Entry-Exit- Long Delay
Y
Allows you to exit during countdown after selecting arming type
and when opened starts countdown before triggering alarm.
Times determined by “Long Entry-Exit Delay” in “Timers” app.
13
Instant Perimeter D/W
Y
Door or window that triggers alarm instantly when system is
armed
14
Instant Interior Door
Y
Interior door that triggers alarm instantly when system is armed
25
Local Safety Sensor
Y
Regardless of arming state, this sensor triggers a chime if it is
opened (non-reporting to central station) Great for medicine
cabinets, pool gates, chemical storage, etc.
8
Reporting Safety
Sensor
Y
Regardless of arming state, this sensor triggers an alarm if it is
opened. Perfect for gun safes, valuables safe, etc.